DESIGN FOR TESTABILITY GUIDELINES
Information Compiled by Scott Cufr
- All test targets are to be on one side of the PCB but both top and bottom are accessible.
- Test Target Priorities: 1) Component Leads 2) Test Pads and 3) Via's
- Center to center spacing between test points or adjacent drilled locations should be as follows:
-
- 1) Two .100" probes with a minimum center to center spacing of .085".
- 2) One .100" probe and one .075" probe with a minimum center to center spacing of .075".
- 3) Two .075" probes with a minimum center to center spacing of .070".
- 4) One .100" probe and one .050" probe with a minimum center to center spacing of .070".
- 5) One .075" probe and one .050" probe with a minimum center to center spacing of .060".
- 6) Two .050" probes with a minimum center to center spacing of .050".
- Test targets should be at least .050" away from components on the side of the PCB being tested.
- Test points are to be distributed evenly over the surface of the PCB. Areas of high probe density should be avoided.
- The preferred size of test targets is .035" (or .040" on top-side targets). Square pads are preferred, due to the increased target area (27%) over the round shaped targets. Targets that are less than .030" will require the probe tips to be guided to the targets.
- Solder mask should not cover any test pads or vias.
- Test targets should be at least .100" away from the edge of the PCB or "break-away" areas. This will allow the gasketing material to meet evenly with the board surface and create a good vaccum seal.
- PCB's should have a minimum thickness of .062". This helps minimize board flex.
- Tooling hole diameters should preferably be .125". The tolerances should be held at +.002/-.001 and the locations should be placed in opposite corners.
- Tooling hole to pad tolerance should be +/- .002".
- Avoid placing nodes on SMT devices. This can cause damage to the device and provides minimal probe contact area.
- Avoid placing test points on excessively long leads (.170" or more). Additional machining may be required for leads of this length and probe contact is compromised due to deflection.
|
|
This site has been optimized for Netscape v1.1 or later.