HC125A-TT Series

Probe Specifications
Plunger Gold-plated hardened BeCu
Body Gold-plated nickel silver
Spring Silver-plated stainless steel
Electrical Resistance <20 milliohms
Maximum Current 45 amps
Plunger Travel .250 (6.35)
The HC125A-TT is designed to be used with the SR125 receptacle. The recommended mounting hole is .141/.143 (3.58/3.63mm). The recommended drill is a 3.6mm. Use tool T125-0 for installation.
Spring Force in oz. (grams)
Spring Type Initial Working Travel
Standard 6.0 (170) 16.0 (454)
 
How to Order (top)

For each probe, specify the probe model and tip style as shown in the example below. If required, specify the optional non-standard spring force.

Example:

Order Form