K-50L-QG High-Frequency
Coaxial and Measurement
Probes
How to Order

|
|
|
|
|
Probe Specifications (at full compression)
|
Replacement Probe: |
SPL-01L-039 |
Applications: |
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the new K-50 R.F. Circuit Design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results. The K-50 was developed in cooperation with a leading manufacturer of advanced communications systems and is supported by a leading instrument equipment manufacturer. |
|
Nominal Impedance: |
50 Ohms |
Minimum Return
Loss @ 1 Ghz: |
23 db, 26 db Typical |
Maximum Insertion
Loss @ 1 Ghz: |
0.12 db, 0.06 db Typical |
Maximum
VSWR @ 1 Ghz: |
1.15:1, 1.11:1 Typical |
|
Materials and Finishes |
Housing: |
Gold plated copper zinc alloy |
Dielectric: |
Premium virgin teflon per MIL-P-18468 |
Replaceable Probes: |
Gold plated beryllium copper alloy. Request SPL-01L-039. |
SMA Connector Pin: |
Gold plated beryllium copper |
Consult factory for more information |
|
|
How to Order
Order Form
|
©1998-2003 Everett Charles Technologies. All rights reserved. Everett Charles Technologies, 700 E. Harrison Ave., Pomona, CA, 91767, U.S.A.
|