Probe Specifications |
Mechanical |
Full Travel: |
.250 (6.35) |
Recommended Working Travel: |
.167 (4.24) |
Mechanical Life Exceeds: |
.25 x 106 cycles |
|
Operating Temperature |
-55°C to +150°C |
Consult factory for other temperature requirements, and applications below -40° |
|
Electrical (Static Conditions) |
Current Rating |
15 amps |
Maximum continuous current, non-inductive at working travel |
|
Probe Resistance |
25 milliohms |
With a standard deviation of <3 milliohms @ 25 mA test current |
|
Materials and Finishes |
Plunger: |
Heat-treated beryllium copper, gold plated over hard nickel |
Barrel: |
Work-hardened nickel silver, silver plated (I.D. and O.D.) over hard nickel |
Spring: |
Stainless steel, silver plated |
Ball: |
Brass, gold plated |
|
|
Receptacle Specifications |
Use SPR Series: |
SPR-3 series |
|
NOTE: The wire gauge listed on the referenced pages is for typical ATE applications only. Larger wire size may be required for other applications. |
|
|
HCP-13 High-Current Probe Test Center .125 (3.18)
Tips
Spring Force
How to Order

|
|
|
Tips (top)

Spring Force (top)
Spring Force in 0z. (grams) |
Spring Type |
|
Preload |
2/3 Travel |
HCP-13 |
|
1.54 (44) |
4.5 (128) |
How to Order (top)
For each probe, specify the probe model and tip style as shown in the example below. If required, specify the optional non-standard spring force.
Example:

Order Form
|